None
1. Cap Screw 2. X-Y Shifter 3. Gasket |
Remove cable ties from motor wires. Disconnect Transmission Harness from the Rail Position Sensor and the Gear Position Sensor.
Disconnect the Rail Select and Gear Select Motors from the Transmission ECU (TECU).
Using a 9/16” socket, remove the 4 mounting cap screws.
Remove X-Y Shifter and gasket.
Ensure Shift Blocks are in the Neutral position, then move Shift Finger to the center (Neutral) location.
Note: If the Shift Finger is not properly aligned, the X-Y Shifter will not fit properly at its mounting location.
Clean and remove old gasket material from Shift Bar Housing. Then, install new gasket on the Shift Bar Housing.
Note: Apply Eaton sealant part number 71205 or equivalent to the mounting cap screws before installing.
The dowel pin on the X-Y Shifter must be aligned with hole in the Shift Bar Housing.
Position X-Y Shifter on the Shift Bar Housing. Using a 9/16” socket, install mounting cap screws and tighten in a cross pattern as follows:
Reconnect the Rail Position Sensor and Gear Position Sensor.
Reconnect the Transmission Harness to the Rail Select and Gear Select Motors. Using cable ties, secure motor wires to the Transmission in their previous position.
To operate properly, the system must be calibrated as follows: