Fault Code 206: TCM Program Memory

J1939: SA 3 SPN 628 FMI 2, 11, 12, 13, 14, 31

Overview

The Endurant XD Transmission is equipped with a Transmission Control Module (TCM). The TCM communicates with other vehicle Electronic Control Units (ECUs), receives feedback from sensors and actuates solenoids to control transmission performance. The TCM is mounted to the transmission and connected to the 20-Way TCM Vehicle Harness Connector and 20-Way TCM Body Harness Connector. The TCM is connected to the transmission sensors and solenoids at the 74-Way Transmission Harness Connector.

Detection

The TCM performs a self-check during operation. If a failure is detected, the fault is set Active.

Conditions to Set Fault Code Active

FMI 2 – Data Erratic: The TCM detected the calibration file is incompatible with the application software version.

FMI 11 – Root Cause Unknown: The TCM detected an internal processing error.

FMI 12 – Bad Intelligent Device: The TCM detected an internal processing error.

FMI 13 – Out of Calibration: The TCM detected an internal processing error.

FMI 14 – Special Instructions: The TCM detected the calibration file is incompatible with the application software version.

FMI 31 – Condition Exists: The TCM has detected that the End Of Line Test Calibration file is present.

Fallback

FMI 2, 11, 14:

  • Amber warning lamp on
  • Engine cranking prohibited
  • Inertia Brake activation prohibited
  • Upshifts prohibited
  • Non-Neutral modes prohibited
  • PTO Mode prohibited
  • Clutch engagements may be harsh

FMI 12, 13:

  • Amber warning lamp on
  • No degraded modes

FMI 31:

  • Amber warning lamp on
  • Coast Mode and Neutral Coast prohibited
  • Upshifts prohibited
  • High start gears prohibited

Conditions to Set Fault Code Inactive

FMI 11, 12, 13: Key cycle and fault condition no longer exist.

FMI 2, 14, 31: Correct calibration file is configured in the TCM.

Possible Causes

FMI 11, 12,13:

  • TCM
    • Software issue
    • Internal failure

FMI 2, 14, 31:

  • TCM
    • Incorrect calibration file configured in the TCM

Additional Tools

  • Endurant XD Service Manual TRSM0960

Fault Code 206 Troubleshooting

A
Purpose:Check for active or inactive fault codes.
  1. Set vehicle parking brake and chock wheels.

  2. Record transmission fault codes, FMIs, occurrences, and timestamps from Service Activity Report created during the Diagnostic Procedure.

  • If Fault Code 206 FMI 11, 12, 13 is Active or Inactive, Go to Step B

  • If Fault Code 206 FMI 2, 14 or 31 is Active, contact Eaton Cummins Automated Transmission Technologies at +1 800-826-4357 for further diagnostic instructions. Go to Step V

  • If Fault Code 206 FMI 2, 14 or 31 is Inactive, the correct calibration file is installed. Go to Step V

B
Purpose:Verify TCM software.
  1. Key off.

  2. Allow TCM to perform a complete power down.

  3. Key on with engine off.

  4. Connect ServiceRanger.

  5. Go to “Programming”.

  6. Under "Software Information", record TCM software in table.

TCM Software
V
Purpose:Verify repair.
  1. Key off.

  2. Reconnect all connectors and verify all components are properly installed.

  3. Key on with engine off.

  4. Connect ServiceRanger.

  5. Go To “Fault Codes”.

  6. Select “Clear All Faults”.

  7. Operate vehicle and attempt to reset the fault code or duplicate the previous complaint.

  8. Check for fault codes using ServiceRanger.